Applied standard
IEC 60502-1:2009
Construction / Materials
Rate voltage : 0.6/1(1.2)kV
Insulation : Type XLPE
Number of conductor : 3 core

Nominal Area
|
Diameter conductor
|
Nominal thickness insulation
|
Thickness Inner sheath
|
Diameter Wire Armour
|
Thickness tape armor
|
Nominal Thickness Outer sheath
|
Approx. Overall Cable Diameter
|
Approx. Weight Copper conductor
|
Approx. Weight Aluminium conductor
|
Nominal Drum Length
|
|
|
|
GSWA
|
DSTA
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
kg/km
|
kg/km
|
kg/km
|
kg/km
|
kg/km
|
kg/km
|
m
|
m
|
m
|
1.5
|
1.56
|
0.7
|
1.0
|
0.9
|
-
|
-
|
1.8
|
1.8
|
-
|
12
|
15
|
-
|
160
|
390
|
-
|
-
|
-
|
-
|
2,000
|
2,000
|
-
|
2.5
|
2.01
|
0.7
|
1.0
|
0.9
|
-
|
-
|
1.8
|
1.8
|
-
|
13
|
16
|
-
|
200
|
470
|
-
|
-
|
-
|
-
|
2,000
|
2,000
|
-
|
4
|
2.55
|
0.7
|
1.0
|
0.9
|
1.0
|
0.2
|
1.8
|
1.8
|
1.8
|
14
|
17
|
17
|
260
|
560
|
430
|
-
|
-
|
-
|
2,000
|
2,000
|
2,000
|
6
|
3.12
|
0.7
|
1.0
|
1.25
|
1.0
|
0.2
|
1.8
|
1.8
|
1.8
|
15
|
18
|
18
|
330
|
720
|
520
|
-
|
-
|
-
|
2,000
|
1,000
|
2,000
|
10
|
4.05
|
0.7
|
1.0
|
1.25
|
1.0
|
0.2
|
1.8
|
1.8
|
1.8
|
17
|
20
|
20
|
480
|
870
|
610
|
-
|
-
|
-
|
2,000
|
1,000
|
2,000
|
16
|
4.65
|
0.7
|
1.0
|
1.25
|
1.0
|
0.2
|
1.8
|
1.8
|
1.8
|
18
|
22
|
22
|
620
|
1,110
|
820
|
330
|
820
|
550
|
2,000
|
1,000
|
2,000
|
25
|
5.9
|
0.9
|
1.0
|
1.6
|
1.0
|
0.2
|
1.8
|
1.8
|
1.8
|
22
|
27
|
25
|
930
|
1,680
|
1,180
|
470
|
1,220
|
730
|
2,000
|
1,000
|
2,000
|
35
|
6.9
|
0.9
|
1.0
|
1.6
|
1.0
|
0.2
|
1.8
|
1.8
|
1.8
|
24
|
30
|
28
|
1,230
|
2,040
|
1,500
|
590
|
1,400
|
870
|
2,000
|
1,500
|
1,500
|
50
|
8.0
|
1.0
|
1.0
|
1.6
|
1.0
|
0.2
|
1.8
|
1.9
|
1.8
|
27
|
32
|
31
|
1,620
|
2,560
|
1,930
|
760
|
1,700
|
1,080
|
1,500
|
1,000
|
1,000
|
70
|
9.8
|
1.1
|
1.2
|
2.0
|
1.2
|
0.2
|
1.9
|
2.0
|
1.9
|
32
|
37
|
35
|
2,290
|
3,650
|
2,680
|
1,040
|
2,440
|
1,440
|
1,500
|
1,000
|
1,000
|
95
|
11.4
|
1.1
|
1.2
|
2.0
|
1.2
|
0.2
|
2.0
|
2.2
|
2.1
|
36
|
42
|
41
|
3,090
|
4,630
|
3,900
|
1,340
|
2,890
|
2,180
|
1,000
|
500
|
500
|
120
|
12.8
|
1.2
|
1.2
|
2.0
|
1.2
|
0.5
|
2.1
|
2.3
|
2.3
|
39
|
46
|
45
|
3,850
|
5,540
|
4,780
|
1,660
|
3,340
|
2,590
|
500
|
500
|
500
|
150
|
14.2
|
1.4
|
1.4
|
2.5
|
1.4
|
0.5
|
2.3
|
2.5
|
2.4
|
44
|
52
|
50
|
4,760
|
7,110
|
5,840
|
2,040
|
4,400
|
3,120
|
500
|
500
|
500
|
185
|
15.8
|
1.6
|
1.4
|
2.5
|
1.4
|
0.5
|
2.4
|
2.6
|
2.5
|
49
|
56
|
55
|
5,930
|
8,530
|
7,120
|
2,520
|
5,120
|
3,710
|
500
|
500
|
500
|
240
|
18.1
|
1.7
|
1.6
|
2.5
|
1.6
|
0.5
|
2.6
|
2.8
|
2.7
|
55
|
63
|
61
|
7,710
|
10,750
|
9,130
|
3,220
|
6,250
|
4,650
|
500
|
300
|
300
|
300
|
20.4
|
1.8
|
1.6
|
2.5
|
1.6
|
0.5
|
2.8
|
3.0
|
2.9
|
61
|
69
|
67
|
9,610
|
12,900
|
11,150
|
3,980
|
7,280
|
5,520
|
250
|
250
|
250
|
400
|
23.2
|
2.0
|
1.6
|
2.5
|
1.6
|
0.5
|
3.0
|
3.2
|
3.1
|
68
|
76
|
75
|
12,300
|
15,950
|
14,000
|
5,080
|
8,780
|
6,820
|
250
|
250
|
250
|
UnAr = Unarmoured; GSWA = Galvanized Steel Wire Armoured; DSTA = Double Steel Tape Armoured; 16mm2 ~ 400mm2 conductors are circular strand compacted