Applied standard
IEC 60502-1:2009
Construction / Materials
Rate voltage : 0.6/1(1.2)kV
Insulation : Type XLPE
Number of conductor : 4 core

Nominal Area
|
Nominal thickness insulation
|
Thickness Inner sheath
|
Diameter Wire Armour
|
Thickness tape armor
|
Nominal Thickness Outer sheath
|
Approx. Overall Cable Diameter
|
Approx. Weight Copper conductor
|
Approx. Weight Aluminium conductor
|
Nominal Drum Length
|
Phase
|
Earth
|
Phase
|
Earth
|
GSWA
|
DSTA
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
UnAr
|
GSWA
|
DSTA
|
mm2
|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
kg/km
|
kg/km
|
kg/km
|
kg/km
|
kg/km
|
kg/km
|
m
|
m
|
m
|
10
|
6
|
0.7
|
0.7
|
1.0
|
1.0
|
1.25
|
0.2
|
1.8
|
1.8
|
1.8
|
17
|
22
|
20
|
510
|
990
|
740
|
280
|
760
|
-
|
2,000
|
2,000
|
2,000
|
16
|
10
|
0.7
|
0.7
|
1.0
|
1.0
|
1.25
|
0.2
|
1.8
|
1.8
|
1.8
|
19
|
24
|
21
|
720
|
1,260
|
920
|
370
|
910
|
570
|
2,000
|
2,000
|
2,000
|
25
|
16
|
0.9
|
0.7
|
1.0
|
1.0
|
1.6
|
0.2
|
1.8
|
1.8
|
1.8
|
23
|
28
|
25
|
1,080
|
1,910
|
1,330
|
530
|
1,360
|
770
|
2,000
|
1,500
|
2,000
|
35
|
16
|
0.9
|
0.7
|
1.0
|
1.0
|
1.6
|
0.2
|
1.8
|
1.8
|
1.8
|
25
|
30
|
26
|
1,380
|
2,270
|
1,640
|
650
|
1,540
|
910
|
2,000
|
1,000
|
1,000
|
50
|
25
|
1.0
|
0.9
|
1.0
|
1.0
|
1.6
|
0.2
|
1.8
|
1.9
|
1.9
|
28
|
34
|
30
|
1,850
|
2,880
|
2,170
|
850
|
1,880
|
1,160
|
1,500
|
1,000
|
1,000
|
70
|
35
|
1.1
|
0.9
|
1.2
|
1.2
|
2.0
|
0.2
|
1.9
|
2.1
|
2.0
|
33
|
39
|
35
|
2,590
|
4,060
|
3,000
|
1,140
|
2,620
|
1,540
|
1,000
|
500
|
500
|
95
|
50
|
1.1
|
1.0
|
1.2
|
1.2
|
2.0
|
0.5
|
2.1
|
2.2
|
2.1
|
37
|
43
|
39
|
3,530
|
5,180
|
4,290
|
1,510
|
3,150
|
2,370
|
500
|
500
|
500
|
120
|
70
|
1.2
|
1.1
|
1.2
|
1.2
|
2.0
|
0.5
|
2.2
|
2.3
|
2.3
|
42
|
48
|
45
|
4,480
|
6,380
|
5,490
|
1,880
|
3,770
|
2,880
|
500
|
500
|
500
|
150
|
70
|
1.4
|
1.1
|
1.4
|
1.4
|
2.5
|
0.5
|
2.3
|
2.5
|
2.4
|
45
|
53
|
48
|
5,350
|
7,860
|
6,450
|
2,230
|
4,720
|
3,320
|
300
|
500
|
500
|
185
|
95
|
1.6
|
1.1
|
1.4
|
1.4
|
2.5
|
0.5
|
2.5
|
2.7
|
2.6
|
51
|
58
|
53
|
6,790
|
9,590
|
7,990
|
2,820
|
5,600
|
4,000
|
300
|
500
|
500
|
240
|
120
|
1.7
|
1.2
|
1.6
|
1.6
|
2.5
|
0.5
|
2.7
|
2.9
|
2.8
|
57
|
65
|
59
|
8,750
|
12,000
|
10,160
|
3,560
|
6,750
|
4,940
|
250
|
250
|
250
|
300
|
150
|
1.8
|
1.4
|
1.6
|
1.6
|
2.5
|
0.5
|
2.9
|
3.0
|
2.9
|
63
|
71
|
65
|
10,900
|
14,400
|
12,410
|
4,380
|
7,840
|
5,870
|
200
|
250
|
250
|
300
|
185
|
1.8
|
1.6
|
1.6
|
1.6
|
2.5
|
0.5
|
2.9
|
3.1
|
3.0
|
64
|
73
|
66
|
11,300
|
14,850
|
12,840
|
4,540
|
8,100
|
6,070
|
250
|
250
|
250
|
400
|
240
|
2.0
|
1.7
|
1.8
|
1.8
|
3.15
|
0.5
|
3.1
|
3.4
|
3.2
|
69
|
79
|
74
|
14,430
|
19,230
|
16,300
|
5,720
|
10,590
|
7,600
|
250
|
250
|
250
|
UnAr = Unarmoured; GSWA = Galvanized Steel Wire Armoured; DSTA = Double Steel Tape Armoured; 16mm2 ~ 400mm2 conductors are circular strand compacted